Ŀ                           Ŀ
 UVC Microscope Viewer for OS/2 Ĵ UvcScope11.zip 
                           

 UVC Microscope Viewer operates your UVC microscope at 640x480 resolution.
 Take a look at specimen and take snapshots. Made in Holland by Wim Brul.

 More information at: http://home.hccnet.nl/w.m.brul/uvcscope/index.html

 Open Source product with its ISC license contained in the LICENSE file.
 Source Code at http://home.hccnet.nl/w.m.brul/uvcscope/UvcScope11s.zip

Ŀ                                          Ŀ
 UVC Microscope Viewer Ĵ uvcscope 
                                          

 UVC Microscope Viewer operates your UVC microscope at 640x480 resolution.
 Use "uvcscope /u" to view yuyv images. Use "uvcscope /m" to view mjpg images.
 Use "uvcscope /c" or "uvcscope /c1" or "uvcscope /c2" to correct yuyv colors.

 The maximize button switches between 640x480 and 320x240 display modes.

 Click on "Snapshot" to take a picture. The snapshot will be written to the
 UVCSCOPE.BMP and UVCSCOPE.JPG files and REXX/2 is started with UVCSCOPE.CMD
 for post processing. You may replace UVCSCOPE.CMD with your own version.

 Click on "Testshot" to capture raw input data. Captured raw input data will
 be written to UVCSCOPE.RAW for later inspection. This could be of help in
 situations where your UVC microscope is working but the displayed picture
 stays black. Use "uvcscope /x" to include stream headers.

Ŀ
 Program Parameters 


 /cN - Select yuyv conversion matrix and transfer characteristics.
 Proper values for N are 0 to 2 (ITU-R BT.601). Default is 3 (ITU-R BT.709).

 /fN - Select Nth discrete frame interval setting.
 Proper values for N are 0 up to the highest setting your microscope supports.

 /iN - Select Nth alternate interface setting.
 Proper values for N are 1 up to the highest setting your microscope supports.

 /m - Select mjpg images.
 This parameter is mutually exclusive with the /u parameter.

 /u - Select yuyv images.
 This parameter is mutually exclusive with the /m parameter.

 /x - Extended "Testshot" stream capture.
 Includes stream headers when capturing raw input data.

Ŀ
 Microscope Selection Parameter 


 /d0000:0000:0000 - device, specifies UVC microscope.

 The 1st part is idVendor, the Vendor Identification.
 The 2nd part is idProduct, the Product Identification.
 The 3rd part is bcdDevice, the Device Release Number.

 Must be specified with valid hexadecimal digits.
 Valid hexadecimal digits are 0 thru 9 and A thru F.
 An invalid character truncates the hexadecimal number.
 The wildcard character # may be specified too.
 Leading zeroes may be omitted.

Ŀ
 Rexx Post Processing 


 UVCSCOPE.CMD uses GBMSIZE.EXE (part of GBM Tools) to convert the snapshot
 into a 320x240 portable network graphics when you remove the /* and */
 from the following line:

 /*'gbmsize.exe -h 240 -w 320 uvcscope.bmp uvcscope.png'*/

 Any string returned by UVCSCOPE.CMD will be shown in a dialog window.
 The FAILURE condition indicates that GBMSIZE.EXE could not be found.